Drainage and Sewage Pumps | Cost, Types, Installation & Selection Guide

Water must be removed from these areas. Excess water within basement/inspections pits/combination systems can cause damage to floor surfaces, walls, electrical connections and contents. Within residential, residential or commercial environments, drainage and sewage pumps can be fitted to remove unwanted water and discharge it into an approved location.

Consider the liquid type, distance to be travelled and site conditions to select the correct pump type.

Where Pumps Should Be Installed

If the discharge pipe is below the inlet level, gravity can be used to discharge the water. However in some properties, such as those with basements, low-level loos, deep pits or discharge points below municipal sewers, pumps must be installed to raise the wastewater to a higher discharge level.

Pumps can be commonly installed in basements, car parks, plant rooms, hotels, restaurants, housing developments and small industrial areas.

In Punjab, heavy rainfall during the monsoon period can cause issues with drainage. Consider local site conditions, such as the lowest floor level, local stormwater routing, sewer level and risk of run-off entering via ramps and open spaces. Only link rainwater to the sewer if allowed by local regulations and system design.

Pump Types

Drainage pumps are typically used to pump relatively dirty or ground water. They may be installed in a sump pit, basement collection pit or low service area. Not all drainage pumps can pump solids. The permissible dimensions of solid components and the requisite liquid medium are contingent upon the specific model configuration. 

Sewage pumps are used to pump wastewater. Some include vortex impellers to help avoid blockages. Channel impellers may be more appropriate depending on the flow rate and head requirement.

Ebara DW submersible pumps are available from the product range. These pumps feature corrosion resistant stainless steel construction, double mechanical seals, and have options to pump solids up to 50mm. Please check exact specification of the model you wish to install.

Submersible pumps are useful to save space in the property, however care should be taken to ensure the sump pit allows safe installation and maintenance. Consider space available, maintenance requirements and refer to manufacturer guidance.

Comparing Pumps

It is important to consider more than just the motor power. Even if two pumps have similar kW values, the flow rate and height may differ. Ensure the pump curve is known, and look at the duty point to see if it meets your requirement.

Comparison Considerations

  • Liquid Type
  • Clean / Dirty / Sewage
  • Solid Content
  • Maximum solid size, risk of blockage
  • Flow
  • Litres per minute (or m 3/h)
  • Head
  • Total vertical lift and losses in pipework, fittings etc.
  • Material
  • Corrosion resistance of material used
  • Controls
  • Float switch, level detection and alarms
  • Serviceability

Availability of spares and qualified support.

Vortex impellers may be useful to avoid blockages, whilst channel impellers may be more appropriate for your desired head and flow. Consider the characteristics of the wastewater in your property and match these to the correct impeller type, solids passing capability and operation.

Cost

Consider the overall cost of the installation. This may include the pump, sump pit, grilles, pipework, valves, electrical box, level controls, alarms, wiring, installation, testing and future servicing.

Installing duplicate pumps may be more expensive initially, but can offer a back-up option. Consider the consequence of failure, and what standard of continuity is required, to decide if duplication is required.

Request quotes from suppliers based on the same information. Include pump model, duty flow, total head, solids capability, material, control type, warranty, delivery and commissioning in the quote. Ask for separate costs for optional features, such as alarms, back up systems and service visits.

Installation Considerations

Conduct a site survey. Find out the chamber size, inlet and outlet levels, discharge route and available electricity. Work out the total dynamic head (vertical head and losses in pipework, elbows, valves and fittings).

If discharging pipework is too small, losses may be increased. If the sump pit design is not ideal, problems may occur.

Ensure the drainage and sewage pumps are installed at the precise depth and in the proper orientation. Leave float switch free to move and install level sensors so that they switch the pump on/off at the correct levels. Fit non return valves to reduce backflow from discharge, and isolation valves if required for maintenance.

Summary

  • Ensure equipment is chosen to suit the liquid and solids.
  • Ensure pump is correctly sized for flow rate, total head and pump curve (rather than just motor power).
  • Consider total installation cost including controls, pipework and maintenance.
  • Ensure safe access, suitable electrical protections and reliable level controls.
  • Ensure regular inspection and alarms to reduce risk of flooding.
  • Ebara DW submersible pumps are available from KK Tech Eco Products. These can be used to pump both domestic and industrial waste. Different impeller types are available to suit your requirements, and corrosion resistant.

FAQ

1. What is the difference between drainage pumps and sewage pumps?

Drainage pumps are typically used with dirty water, whereas sewage pumps are used for wastewater with solids. Ensure the liquid and solid capabilities of the pump model match your needs.

2. What pump size do I need?

Calculate the maximum flow, required discharge rate and total dynamic head. Get the Duty Point checked from the manufacturers pump performance curve by a pump supplier.

3. Can a submersible sewage pump be used to pump solid waste?

Some models can be used with solid waste. The maximum solid size varies – please check the pump for solid capability. Avoid pumping wipes, cloths or inappropriate materials.

4. Should I install an automatic pump in my basement?

If water is collected at a lower level than gravity can discharge, then it is common to install an automatic system with suitable level controls. Consider installing alarms and back-up.

5. What influences the cost of installation?

The pump type, size, head, sump construction, length of pipework, number of valves, controls, electrical, accessibility and commissioning will influence the cost.